Working-temperature range | 5 °C above ambient temperature up to +50 °C Standard sterilisation programme: 60 minutes at 180°C (without removing the sensors) |
---|---|
Setting temperature range | +18 to +50 °C |
Setting accuracy temperature | 0.1 °C |
Temperature | 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value |
Setting range active humidity control | 40 to 97 % rh and rh-Off |
---|---|
Setting accuracy humidity | 0.5 % rh |
Humidity control | Humidity limitation thanks to a Peltier element; when water dish is full and inserted, the Peltier element limits the value of relative humidity in the interior to 93 % rh +/- 2.5 % |
CO2 control | Digital electronic CO2 control with dual beam NDIR system, with auto-diagnostic system and acoustic fault indication, barometric pressure compensation |
---|---|
Adjustment range CO2 | 0 to 20 % CO2 |
Variation in time CO2 | +/- 0.2 % CO2 |
Adjustment range O2 | 1 to 20 % O2 |
Setting accuracy O2 | 0.1 % O2 |
ControlCOCKPIT | TwinDISPLAY. Adaptive multifunctional digital PID-microprocessor controller with 2 high-definition TFT-colour displays. |
---|---|
Language setting | German, English, Spanish, French, Polish, Czech, Hungarian |
Function SetpointWAIT | the process time does not start until the set temperature is reached |
adjustable parameters | temperature (Celsius or Fahrenheit), fan speed, CO2, programme time, time zones, summertime/wintertime |
Interface | Ethernet LAN, USB |
---|---|
Documentation | programme stored in case of power failure |
Programming | AtmoCONTROL software on a USB stick for programming, managing and transferring programmes via Ethernet interface or USB port |
Autodiagnostic system | integral fault diagnostics for temperature, CO2 and humidity limit control |
---|---|
Alarm | visual and acoustic |
6 sides | large-area multi-function heating system on four sides with additional door and back heating to avoid condensation |
---|
Works calibation certificate °C & CO2 | incl. works calibration certificate (measuring point chamber centre) at +37°C, 5 % CO2 for standard units |
---|---|
Works calibration cerfificate °C, CO2 & rH | incl. works calibration certificate for +37°C, 5 % CO2 and 90 % rh (requires option K7); standard equipment for units with active humidity control |
Works calibration certificate °C, CO2, rH & O2 | incl. works calibration certificate for +37°C, 5 % CO2, 90 % rh and 10 % O2 (requires option K7 and option T6); Standard equipment for units with O2 control |
Internals | 2 pcs stainless steel shelves, perforated |
Internals | 1 pc stainless steel water dish |
Door | fully insulated stainless steel door with 2-point locking (compression door lock) |
Door | inner glass door with opening (8 mm Ø) to take gas sample |
Interior | material 1.4301 (ASTM 304), corrosion resistant |
---|---|
Volume | 241 l |
Dimensions W x H x D in mm | w(A) x h(B) x d(C): 600 x 810 x 500 mm |
Max. number of grids/shelves | 12 |
Max. loading of chamber | 140 kg |
Max. loading per grid/shelf | 15 kg |
Dimensions | w(D) x h(E) x d(F): 759 x 1176 x 691 mm |
---|---|
Housing | rear zinc-plated steel |
Voltage Electrical load | 230 V, 50/60 Hz approx. 2000 W |
---|---|
Voltage Electrical load | 115 V, 50/60 Hz approx. 2000 W |
the appliances must be transported upright | |
---|---|
Customs tariff number | 8419 8998 |
Country of origin | Federal Republic of Germany |
WEEE-Reg.-No. | DE 66812464 |
Dimensions approx incl. carton | B x H x T: 840 x 1360 x 900 mm |
Net weight | approx. 110 kg |
Gross weight carton | approx. 145 kg |